Контроллер приоритета вызова EXTRON PPC 25, 60-887-01
PPC 25
Priority Page Controller
The PPC 25 mutes classroom audio during a page from a public address system. The sensor connects to a PA speaker lead and detects current flow when a PA announcement is initiated. The sensor signals the controller to close its output relay which sends a mute signal to the classroom audio device. The output relay can be connected to any product that has a digital input or contact closure mute control,
Note: The PPC 25 and sensor cable are UL 2043 plenum rated,
ПАРАМЕТРЫ
- Detects audio signal in a public address system speaker and mutes program audio
- Designed for use with PoleVault® Systems and other Extron products with audio mute functionality
- Compatible with 25/
- Adjustable time delay from 2 to 8 seconds for restoring audio after a page
- Eighth rack width,
- Priority Page Sensor and 35 (10.6 m) sensor cable included